Principio de medición:
Presión absoluta y de calibre
Fuente de alimentación:
DC 10-30V
Exactitud:
El ±0.2% del palmo
Protección contra la entrada:
IP67
Rango:
0-10,000 psi
Garantía:
2 años
Tipo de presión:
Presión de calibre
Material de brida:
316SST
Aprobaciones:
CE, ROHS
Materiales mojados:
Acero inoxidable 316L
Material de diafragma:
Cerámico
Rango de temperatura:
-40 a 85 ° C
Mostrar:
Lcd
Elemento de detección de presión:
Piezoresistivo
Clase de protección:
IP65
Resaltar:

Emerson Rosemount 3051 LCD display

,

Rosemount 3051 pressure transmitter

,

industrial pressure transmitter with warranty

Condiciones de pago y envío
Cantidad de orden mínima
1 PC
Precio
USD 120
Tiempo de entrega
7-14 días
Condiciones de pago
T/T
Capacidad de la fuente
100 PC
Descripción del producto

What is the Rosemount 03031 LCD Display (LCD Meter)?

  • The 03031 “LCD meter” is a local display module designed for Rosemount transmitters (such as the Model 3051) to show process readings and diagnostic messages locally.
  • It is not a standalone transmitter; rather, it is installed on or integrated into the transmitter electronics housing as a visual readout.
  • The display module is often offered in “meter kit” form (which includes the display plus mounting and interface parts) or “meter only” form, depending on how the transmitter housing is configured. For example, part number 03031-0193-0103 is a “meter only” version for an improved-style housing.

 

Key Features & Capabilities

From Rosemount’s documentation:

Feature

Description

Display format

Two lines: first line shows up to five digits for the process variable; second line shows engineering units (up to six characters)

Display modes

Can display: engineering units, percent of range, user-configurable scale, or alternate between two modes

User-configurable scale

You can set a custom scale (lower/upper limits, decimal point, units, transfer function) for display independent of the transmitter’s analog output behavior

Diagnostics

Displays abbreviated diagnostic or alarm messages (e.g. error codes) on both lines as needed

Compatibility

Works with Rosemount transmitters that support the LCD meter, such as the Model 3051, 2051, etc.

Power / interface

The LCD meter receives data from the transmitter’s electronics board (via a 10-pin interconnection header) and shows the output directly.

Temperature / environmental limits

Operating temperature: –20 °C to +80 °C (–4 °F to 175 °F)

Installation constraints

Requires an extended cover in the transmitter housing to physically accommodate the LCD module. Also, the display and electronics are electrostatic discharge (ESD) sensitive; care must be taken during handling.

 

Common Part Numbers / Variants

Some variants / kits you may come across include:

  • 03031-0199-0001 — low power LCD display assembly (4–20 mA HART / 1–5 Vdc)
  • 03031-0199-0021 — LCD display with stainless steel cover version
  • 03031-0193-0103 — meter only (no housing cover) version for an improved style housing
  • Other meter kit variants: 03031-0193-0101, 03031-0193-0111, 03031-0193-1101, 03031-0193-1111 etc., matched to different transmitter housing styles

 

How It’s Installed & Used

  • The LCD meter is mounted on the electronics board side of the transmitter housing. It connects via a 10-pin interconnection header.
  • To install, one must remove transmitter covers, install jumpers (alarm, security), insert the new meter into the header, secure it with screws, and attach an extended cover.
  • After installation, the meter must be configured (scale, units, decimal point, etc.) using a HART communicator (e.g. Model 275) or AMS software.
  • Because the meter is ESD sensitive, special handling precautions must be observed when installing or servicing it.

 

Use Cases & Benefits

  • It gives local, real-time display of process variable (pressure, level, flow) without needing to connect to a control room or external display system.
  • It supports on-site diagnostics, letting users see alarm or error codes immediately.
  • The user-configurable scaling feature allows you to present the reading in meaningful engineering units or custom scales (e.g. flow) even if the transmitter’s analog output remains linear.
  • Because it is designed by Rosemount for their transmitters, it integrates cleanly and reliably with their devices.

 